Skip to main content

VX-2000DS AMQ

  • VX-2000DS_Front.jpg
VX-2000DS_Front.jpg

Power Supply

VX-2000DS AMQ

Provides DC distribution and battery backup power to each component in the VX-3000 system.

Supplies the DC power to each component in the VX-2000 system, keeps the batteries charged, ambient temperature controlled charging voltage, and automatic switch-over in case of AC mains failure.

QTY
▼
Power Source
120 V AC, 60 Hz
Power Consumption
240 W max.
DC Power Output (AC mode)
Number of connectable equipment: Up to 3 VM-3240 AMQ, M4 screw terminal, distance between barriers: 11mm
Current Specification
Maximum output current draw from the battery: 43.5 A
Compatible Battery
Panasonic LC-X/LC-P Series (12 V x 2)
Charging Method
Trickle charging
Charging Current
5 A max.
Charging Output Voltage
27.3 V ±0.3 V (at 25 °C or 77 °F)
Temperature correction coefficient: –40 mV/°C
Power Supply Input
6, M4 screw terminal, distance between barriers: 11mm (0.43")
DC Power Output
6 (25 A max, each) M4 screw terminal, distance between barriers: 11 mm (0.43")t
Control Connector
RJ45 female connector for connecting the VM-3000 System
Twisted-pair straight cable (TIA/EIA-568A standard)
Type of control signal: Battery check, AC power status, DC power status, charging circuit failure, and battery failure
Battery Connection
1 pair of positive and negative terminals; Applicable cable diameter: AWG 6 – AWG 0 (AWG 1/0) (16 mm 2 – 50 mm 2) Line resistance within 4 mΩ/ total
Operating Temperature
0°C to +40°C (32 °F to +104 °F)
Finish
Panel: Surface-treated steel plate, black, 30% gloss, paint
Dimensions
82 (W) x 88.4 (H) x 377.6 (D) mm (18.98" x 3.5" x 13.29")
Weight
10.5kg (23.15 lb)
Included Accessories
Rack mounting screw (5x12) x 4, Fiber washer x 4, Blade fuse (40A) x 3, Fuse (T6.3 A L) x 1, Insulating sheet x 1, Thermal insulating sheet x 1, Power cable (2 m) x 1
Fuse Rating
Blade fuse (40 A), Blade fuse (7.5 A), fuse (7.5 A)
Internal Resistance
Maximum internal resistance of the battery and its associatetd circuitry, Ri max. 50 mΩ
Cable Requirements
Recommended cable parameter for DS-SF Link:
Twisted-pair straight cable (TIA/EIA-568A standard)