The VP-2122 Power Amplifier features a 120 W-by-2 channels configuration, and uses the VP-200VX Power Amplifier Module per channel.
- Power configuration: 120 W x 2 Channels
- Usable as standby amplifier for emergency switch over
- Power Amplifier uses 1 VP-200VX Power Amplifier Input Module per channel
- Programmable power amplifier standby function extends battery-powered operation time in emergency cases
Power Source
28 V DC (operating range: 20 – 40 V DC)
M4 screw terminal, distance between barriers: 12 mm
M4 screw terminal, distance between barriers: 12 mm
Current Consumption
0.04 A (standby mode), 0.40 A (no audio input),
4.8 A (1/8 rated output, EN60065), 17 A (rated output) channel total
4.8 A (1/8 rated output, EN60065), 17 A (rated output) channel total
Rated Output
120 W x 2 (at min. resistive and max. capacitive load)
Output Power (at AC Mains: 195.5 V)
90 W x 2 (at min. resistive and max. capacitive load)
Output Voltage
100 V (70 V, 50 V: selectable by internal wiring change)
Minimum Impedance Load
83 Ω (at 100 V), 41 Ω (at 70 V), 21 Ω (at 50 V)
Maximum Capacitive Load
0.25 μF (at 100 V), 0.5 μF (at 70 V), 1 μF (at 50 V)
Number of Channels
2
Input
Specified by input module VP-200VX
Number of Module Slots
2, usable module: VP-200VX
Output
Power amplifier output (speaker line):M3.5 screw terminal, distance between barriers: 8.8 mm
Frequency Response
40 Hz – 16 kHz, ±3 dB (at 1/3 rated output)
Distortion
1% or less (at rated output, 1 kHz)
Signal to Noise Ratio
80 dB or more
Indicator
Channel power indicator: 2 channels, dual color LED
Overheat indicator: Yellow LED
Overheat indicator: Yellow LED
Operating Temperature
0 °C to 40 °C
Finish
Panel: Surface-treated steel plate, black (30% gloss), paint
Dimensions
482 (W) x 88.4 (H) x 345 (D) mm
Weight
9.1 kg
Included Accessories
Rack mounting screw x 4, Fiber washer x 4
Please download Datasheet to access full specifications.
Optional Accessory
2-channel power amplifier with 2 x 120W power on
50V-,, 70V-and 100V-Linien, proof against short circuit and open circuit-sure, overheating protection. Cross flow air flow by means of temperature-controlled fan cooling. Connecting the loudspeaker outputs on screw terminal. Slot for different input modules.
Controllable by the system standby mode with very low power consumption and fast reclosing (< 0.5 seconds).
Controllable by the system standby mode with very low power consumption and fast reclosing (< 0.5 seconds).
Need other technical materials like software, firmware, or EASE files? Please visit our Download Center.
*Sign-in or membership registration is required.
Get Your Quote.
- Products
VP-2122